Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/10396
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDai, K.en
dc.contributor.authorVlessidis, A. G.en
dc.contributor.authorEvmiridis, N. P.en
dc.date.accessioned2015-11-24T16:56:09Z-
dc.date.available2015-11-24T16:56:09Z-
dc.identifier.issn0039-9140-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/10396-
dc.rightsDefault Licence-
dc.subjectperoxynitriteen
dc.subjectnitric oxideen
dc.subjectchemiluminescenceen
dc.subjectcellulose acetate membrane sampleren
dc.subjectnitric-oxideen
dc.subjectluminol chemiluminescenceen
dc.subjecthydrogen-peroxideen
dc.subject3-nitrotyrosineen
dc.subjectsuperoxideen
dc.subjectinjuryen
dc.titleDialysis membrane sampler for on-line flow injection analysis/chemiluminescence-detection of peroxynitrite in biological samplesen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.primaryDoi 10.1016/S0039-9140(02)00463-0-
heal.identifier.secondary<Go to ISI>://000180645600007-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0039914002004630/1-s2.0-S0039914002004630-main.pdf?_tid=9f2d2836-356a-11e3-bdbc-00000aacb35e&acdnat=1381821960_bc9d659f7e3737cb91614eebd3b85bcb-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.publicationDate2003-
heal.abstractPeroxynitrite, as a derivative of nitric oxide, is a potent oxidant. It reacts with several biological molecules, makes cellular and tissue damages, and is related with many diseases; therefore, it is of major concern in current medical research works. In this work, a special perm-selective cellulose acetate membrane sampler is used to implement flow injection analysis (FIA)/chemiluminscence (CL)-detection method for the detection of peroxynitrite with Luminol CL-reagent. Optimum detection conditions were established, and the permeability of peroxynitrite through cellulose acetate (CA) membrane, as well as the interference from matrix constituents were studied. The proposed method has the high sensitivity of the CL-detection and the selectivity of perm-selective membrane sampler. The obtained detection limit of 1 x 10(-11) M (without dialysis membrane) and 1 x 10(-10) M (with dialysis membrane), makes it possible to monitor the elusive peroxynitrite in biological samples. The mechanism of luminol CL-emission generated during oxidation by peroxynitrite and the kinetics of peroxynitrite decomposition were also studied using FIA/CL-detection set-up. (C) 2002 Elsevier Science B.V. All rights reserved.en
heal.publisherElsevieren
heal.journalNameTalantaen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΧΗΜ

Files in This Item:
File Description SizeFormat 
Dai-2003-Dialysis membrane sa.pdf190.74 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons