Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/9233
Full metadata record
DC FieldValueLanguage
dc.contributor.authorMaines, A.en
dc.contributor.authorProdromidis, M. I.en
dc.contributor.authorTzouwara-Karayanni, S. M.en
dc.contributor.authorKarayannis, M. I.en
dc.contributor.authorAshworth, D.en
dc.contributor.authorVadgama, P.en
dc.date.accessioned2015-11-24T16:47:46Z-
dc.date.available2015-11-24T16:47:46Z-
dc.identifier.issn1040-0397-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/9233-
dc.rightsDefault Licence-
dc.subjectamperometric biosensorsen
dc.subjectcitrateen
dc.subjectmodified polymeric membranesen
dc.subjectextended linearityen
dc.subjectglutamate-pyruvate transaminaseen
dc.subjectflow-injectionen
dc.subjectorganic-acidsen
dc.subjectcitric-aciden
dc.subjectchromatographyen
dc.subjectdetectoren
dc.subjectsamplesen
dc.subjectglucoseen
dc.subjectoxidaseen
dc.subjectsensoren
dc.titleAn enzyme electrode for extended linearity citrate measurements based on modified polymeric membranesen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.secondary<Go to ISI>://000089837600005-
heal.identifier.secondaryhttp://onlinelibrary.wiley.com/store/10.1002/1521-4109(200010)12:14<1118::AID-ELAN1118>3.0.CO;2-0/asset/1118_ftp.pdf?v=1&t=h0dzuc0k&s=03a0b0f8f1f90555fe85d909d3e080badfae3236-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.publicationDate2000-
heal.abstractPyruvate oxidase (POD), oxaloacetate decarboxylase (AOCD), and citrate lyase (CL) were coimmobilized (or immobilized separately) in a series of polymeric membranes for the construction of amperometric bisensors of pyruvic, oxaloacetic, or citric acid in concentrated samples. For oxaloacetic acid, POD, and OACD were coimmobilized on dialysis membranes and were used in a multimembrane configuration with an inner spin-coated cellulose acetate (CA) membrane modified with isopropyl myristate (IPM) and an outer diffusion restricted membrane of cellulose acetate modified with a cationic surfactant. These membranes were also tested in a POD laminate containing the cofactors FAD and TPP for monitoring the response stability with duration of exposure to an external electrolyte and found to be effective in reagentless mode, with good pyruvate response stability over 3 h without compromise of signal size. Coimmobilization of POD/OACD and CL on different types of high protein binding membrane such as mixed cellulose ester (HA) was investigated. The relative optimum concentrations of several activators (divalent cations) and cofactors such as FAD and thiamine pyrophosphate (TPP) were investigated with the probe assembled as a pyruvate biosensor. An extended linearity up to 100 mM citric acid was achieved.en
heal.publisherWILEY-VCH Verlagen
heal.journalNameElectroanalysisen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΧΗΜ

Files in This Item:
File Description SizeFormat 
Prodromidis-2000-An enzyme electrode for.pdf198.75 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons