Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/9222
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKiranas, E. R.en
dc.contributor.authorKarayannis, M. I.en
dc.contributor.authorTzouwaraKarayanni, S. M.en
dc.date.accessioned2015-11-24T16:47:41Z-
dc.date.available2015-11-24T16:47:41Z-
dc.identifier.issn0003-2719-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/9222-
dc.rightsDefault Licence-
dc.subjectglycerol kinaseen
dc.subjectimmobilizationen
dc.subjectglycerolen
dc.subjectadenosine triphosphateen
dc.subjectserumen
dc.subjectwinesen
dc.subjectfiaen
dc.subjectflow-injection analysisen
dc.subjectkinaseen
dc.subjectassayen
dc.titleAn enzymatic method for the determination of ATP and glycerol with an automated FIA systemen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.secondary<Go to ISI>://A1997WL67700010-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.publicationDate1997-
heal.abstractA method for the enzymatic determination of adenosine triphosphate (ATP) and glycerol has been developed, using an automated FIA system. The enzymes Glycerophosphate Oxidase (GPO) and Glycerol Kinase (GK) have been immobilized on non-porous glass beads following optimization of the immobilization parameters. The fabricated Single Bead String Reactors (SBSR) were used in connection with a FIA system, following optimization of its parameters. The half-life of GK SBSR, regarding enzyme activity, was found to be 45 days for 90 measurements of daily use and storage at 4 degrees C in the appropriate buffer. The linear dynamic ranges of the working curves for the enzymatic determinations of ATP and Glycerol, were 4-70 mu mol.l(-1) and 2-160 mu mol.l(-1) respectively. Glycerol was determined in white and red wines after a 1:5,100 dilution. Glycerol was also determined in human serum, following deproteinization of the samples by gel filtration. The low limits of quantification (4 mu mol.l(-1) ATP and 1 mu mol.l(-1) glycerol) and accuracies better than 2% for ATP and 1% for glycerol, show that the proposed method offers many significant improvements over the conventional methods.en
heal.journalNameAnalytical Lettersen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΧΗΜ

Files in This Item:
There are no files associated with this item.


This item is licensed under a Creative Commons License Creative Commons