Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/8522
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGiokas, D. L.en
dc.contributor.authorPaleologos, E. K.en
dc.contributor.authorKarayannis, M. I.en
dc.date.accessioned2015-11-24T16:42:13Z-
dc.date.available2015-11-24T16:42:13Z-
dc.identifier.issn0306-7319-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/8522-
dc.rightsDefault Licence-
dc.subjectortho-phosphatesen
dc.subjectmolybdenumen
dc.subjectdiphenylamineen
dc.subjectwastewatersen
dc.subjectspectrophotometryen
dc.subjectspectrophotometric determinationen
dc.subjectsolvent-extractionen
dc.subjectinjection-analysisen
dc.subjecthydrogen-peroxideen
dc.subjectmalachite greenen
dc.subjectorthophosphatesen
dc.subjectvanadiumen
dc.subjectcobalten
dc.titleMonitoring of ortho-phosphates in wastewaters based on the oxidizing effect of molybdenum on diphenylamine in a formic acid solution environmenten
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.primaryDoi 10.1080/0306731021000048609-
heal.identifier.secondary<Go to ISI>://000182752800008-
heal.identifier.secondaryhttp://www.tandfonline.com/doi/pdf/10.1080/0306731021000048609-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.publicationDate2003-
heal.abstractA new approach towards the spectrophotometric determination of ortho-phosphates is described. The method is based on the reaction of phosphate with the by-products of the oxidation reaction between diphenylamine and molybdenum (VI) in a formic acid solution environment. The final product absorbs at 340 nm allowing for the determination of ortho-phosphates at concentrations as low as 0.44 mg L-1 by using a very small sample volume. The calibration curve is linear in the range of 0.5-3 mg L-1 yielding recoveries higher than 96% in various sample matrices. Under the optimum experimental conditions side reactions with other ions that usually have high affinity for molybdenum ions are absent or minimum allowing for the interference free determination of PO43-. The only interference rises from the partial decomposition of organic or acid-hydrolysable phosphorus, which is codetermined with ortho-phosphates as a result of the extreme acidic conditions. However, their effects are minor compared to the interferences usually observed with the traditional methods.en
heal.publisherTaylor & Francisen
heal.journalNameInternational Journal of Environmental Analytical Chemistryen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΧΗΜ

Files in This Item:
File Description SizeFormat 
Giokas-2003-Monitoring of ortho-.pdf168.8 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons