Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/8386
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDemertzis, M. A.en
dc.date.accessioned2015-11-24T16:41:14Z-
dc.date.available2015-11-24T16:41:14Z-
dc.identifier.issn0003-2670-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/8386-
dc.rightsDefault Licence-
dc.subjectlimit spectrophotometryen
dc.subjectbeer's lawen
dc.subject1,10-phenanthrolineen
dc.subjectflow-injection systemen
dc.subjectironen
dc.subject1,10-phenanthrolineen
dc.subjectspeciationen
dc.subjectiron(iii)en
dc.subjectcopperen
dc.subjectcellsen
dc.titleLow detection limit spectrophotometryen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.primaryDoi 10.1016/S0003-2670(03)00512-9-
heal.identifier.secondary<Go to ISI>://000189102800011-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0003267003005129/1-s2.0-S0003267003005129-main.pdf?_tid=d4a64c1c894522509484281f86a3fd8b&acdnat=1333028436_37c7dcd5a8329de16ef33672d4d4f268-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.publicationDate2004-
heal.abstractAn efficient, more sensitive and accurate spectrophotometric process is possible and can be used to obtain qualitative or quantitative results for analytes at limiting concentrations lower than usual. Transmission measurements (incident light power, P-0, or transmitted, P) are performed with a fluorescence spectrometer. One cell only is used to measure standards or unknown solutions, placed between the standard holder cuvette and the emission monochromator of the instrument. The source of the radiant power (P-0) is not the xenon lamp but the fluorescence or scattered radiation from the holder cuvette filled with an appropriate solution. The analyte concentration is found from a calibration graph, based upon Beer's law or the approximate formula P-0 - P = 2.303P(0)epsilonbc, which is valid for dilute solutions. Determination of iron in a reference material, using 1,10-phenanthroline as the chromogenic reagent, was chosen as an example to demonstrate the suitability of the proposed method and clarify several important statistical questions. Also discussed is why and to what extent molecular fluorescence methods are more sensitive than molecular absorption methods. (C) 2003 Elsevier B.V. All rights reserved.en
heal.journalNameAnalytica Chimica Actaen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΧΗΜ

Files in This Item:
File Description SizeFormat 
Demertzis-2004-Low detection limit.pdf76.5 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons