Please use this identifier to cite or link to this item:
https://olympias.lib.uoi.gr/jspui/handle/123456789/8386
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Demertzis, M. A. | en |
dc.date.accessioned | 2015-11-24T16:41:14Z | - |
dc.date.available | 2015-11-24T16:41:14Z | - |
dc.identifier.issn | 0003-2670 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/8386 | - |
dc.rights | Default Licence | - |
dc.subject | limit spectrophotometry | en |
dc.subject | beer's law | en |
dc.subject | 1,10-phenanthroline | en |
dc.subject | flow-injection system | en |
dc.subject | iron | en |
dc.subject | 1,10-phenanthroline | en |
dc.subject | speciation | en |
dc.subject | iron(iii) | en |
dc.subject | copper | en |
dc.subject | cells | en |
dc.title | Low detection limit spectrophotometry | en |
heal.type | journalArticle | - |
heal.type.en | Journal article | en |
heal.type.el | Άρθρο Περιοδικού | el |
heal.identifier.primary | Doi 10.1016/S0003-2670(03)00512-9 | - |
heal.identifier.secondary | <Go to ISI>://000189102800011 | - |
heal.identifier.secondary | http://ac.els-cdn.com/S0003267003005129/1-s2.0-S0003267003005129-main.pdf?_tid=d4a64c1c894522509484281f86a3fd8b&acdnat=1333028436_37c7dcd5a8329de16ef33672d4d4f268 | - |
heal.language | en | - |
heal.access | campus | - |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείας | el |
heal.publicationDate | 2004 | - |
heal.abstract | An efficient, more sensitive and accurate spectrophotometric process is possible and can be used to obtain qualitative or quantitative results for analytes at limiting concentrations lower than usual. Transmission measurements (incident light power, P-0, or transmitted, P) are performed with a fluorescence spectrometer. One cell only is used to measure standards or unknown solutions, placed between the standard holder cuvette and the emission monochromator of the instrument. The source of the radiant power (P-0) is not the xenon lamp but the fluorescence or scattered radiation from the holder cuvette filled with an appropriate solution. The analyte concentration is found from a calibration graph, based upon Beer's law or the approximate formula P-0 - P = 2.303P(0)epsilonbc, which is valid for dilute solutions. Determination of iron in a reference material, using 1,10-phenanthroline as the chromogenic reagent, was chosen as an example to demonstrate the suitability of the proposed method and clarify several important statistical questions. Also discussed is why and to what extent molecular fluorescence methods are more sensitive than molecular absorption methods. (C) 2003 Elsevier B.V. All rights reserved. | en |
heal.journalName | Analytica Chimica Acta | en |
heal.journalType | peer reviewed | - |
heal.fullTextAvailability | TRUE | - |
Appears in Collections: | Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΧΗΜ |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Demertzis-2004-Low detection limit.pdf | 76.5 kB | Adobe PDF | View/Open Request a copy |
This item is licensed under a Creative Commons License