Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/8153
Full metadata record
DC FieldValueLanguage
dc.contributor.authorStalikas, C. D.en
dc.contributor.authorKarayannis, M. I.en
dc.contributor.authorTzouwarakarayanni, S. M.en
dc.date.accessioned2015-11-24T16:39:25Z-
dc.date.available2015-11-24T16:39:25Z-
dc.identifier.issn0003-2654-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/8153-
dc.rightsDefault Licence-
dc.subjectl-glutamic aciden
dc.subjectglutamate oxidaseen
dc.subjectsingle-bead string reactoren
dc.subjectflow injectionen
dc.subjectfood and pharmaceutical samplesen
dc.subjectenzyme electrodeen
dc.subjectascorbic-aciden
dc.subjectinterferenceen
dc.subjectperoxidaseen
dc.subjectreactoren
dc.titleImmobilization of Glutamate Oxidase on Nonporous Glass-Beads - Automated Flow-Injection System for the Assay of Glutamic-Acid in Food Samples and Pharmaceuticalsen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.primary10.1039/an9931800723-
heal.identifier.secondary<Go to ISI>://A1993LJ62300029-
heal.identifier.secondaryhttp://pubs.rsc.org/en/Content/ArticleLanding/1993/AN/an9931800723-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.publicationDate1993-
heal.abstractAn enzymic method is proposed for the determination of glutamic acid in food samples and pharmaceuticals. The method is useful in the range 0.01-0.5 mmol 1-1, with a detection limit of 0.005 mmol l-1 for an injection volume of 52 mul. L-Glutamate oxidase from Streptomyces sp. X-1 19-6 was immobilized on non-porous glass beads, and the H2O2 produced was caused to react with Trinder's reagent. Various parameters were studied for the establishment of the optimum operating conditions for an in-house flow injection manifold with a spectrophotometric detector. Many interfering species and several amino acids were tested in order to verify the specificity of the enzyme reactor. Experimental data for interfering organic and inorganic substances are reported. The system works very selectively for glutamic acid and glutamates. The method is ideally suited to the assay of glutamates in a large number of samples within a single working day, as the frequency is 40 samples h-1. The relative standard deviation is 1.8% for six assays. The immobilized reactor is stable for a long period under proper conditions of storage. The accuracy of the proposed method was tested by comparison of the results with those of the Association of Official Analytical Chemist's method and with the manufacturer's specifications for the analysed samples, where available. Good agreement was obtained. Recovery studies yielded results between 97 and 105%.en
heal.publisherRoyal Society of Chemistryen
heal.journalNameAnalysten
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΧΗΜ

Files in This Item:
There are no files associated with this item.


This item is licensed under a Creative Commons License Creative Commons