Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/7997
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPappas, A. C.en
dc.contributor.authorProdromidis, M. I.en
dc.contributor.authorKarayannis, M. I.en
dc.date.accessioned2015-11-24T16:38:05Z-
dc.date.available2015-11-24T16:38:05Z-
dc.identifier.issn0003-2670-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/7997-
dc.rightsDefault Licence-
dc.subjectflow monitoringen
dc.subjectnadhen
dc.subjectalcohol dehydrogenaseen
dc.subjectpyruvate decarboxylaseen
dc.subjectacetaldehydeen
dc.subjectpyruvateen
dc.subjectinjection analysisen
dc.subjectamperometric biosensorsen
dc.subjectethanolen
dc.subjectenzymesen
dc.subjectwinesen
dc.titleFlow monitoring of NADH consumption in bioassays based on packed-bed reactors bearing NAD(+)-dependent dehydrogenases - Determination of acetaldehyde using alcohol dehydrogenaseen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.secondary<Go to ISI>://000177899000024-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0003267002001952/1-s2.0-S0003267002001952-main.pdf?_tid=34b6b4135cf67d109c9223595155effb&acdnat=1333037244_73f99476c453f7128d34b4e0aa945dd3-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.publicationDate2002-
heal.abstractAn enzymatic method for the individual or simultaneous determination of pyruvic acid and acetaldehyde is described. Alcohol dehydrogenase (ADH) was immobilized onto aminopropyl-modified controlled pore glass, which was then used for the construction of packed-bed (PB) reactors. ADH catalyses the reduction of acetaldehyde to ethanol, in the presence of the coenzyme NADH, which is oxidized to NAD(+). Photometric measurements in a fully automated flow injection (FI) manifold are used to monitor the decrease of NADH absorbance at 340 run. The possibility of pyruvate measurements, by combining the above mentioned system with soluble pyruvate decarboxylase (PyDC) is also demonstrated. PyDC catalyses the decarboxylation of pyruvate to acetaldehyde. Analytical parameters such as the buffering system, working pH, flow rate, sample size, and NADH concentration were studied. The interference of various compounds present in real samples was also investigated. Linear calibration graphs over the ranges 0.08-1.25 and 0.04-0.4 mM acetaldehyde were constructed in the presence of 50 mM succinate pH 7.5 and 50 mM phosphate pH 7.0 buffering systems, respectively. A linear calibration graph over the range 0.08-1.25 mM pyruvate was also constructed in the presence of 50 mM succinate pH 7.5 buffer solution. The reactors remain active for more than 6 months under specified storage conditions. The maximal sample throughput is 30 h(-1) and the R.S.D. of the method is 0.9% for 0.2 mM acetaldehyde (n = 6). The suitability of the proposed method for real samples was tested by recovery studies. (C) 2002 Elsevier Science B.V. All rights reserved.en
heal.publisherElsevieren
heal.journalNameAnalytica Chimica Actaen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΧΗΜ

Files in This Item:
File Description SizeFormat 
Prodromidis-2002-Flow monitoring of.pdf98.1 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons