Please use this identifier to cite or link to this item:
https://olympias.lib.uoi.gr/jspui/handle/123456789/24258
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Michalis, L. K. | en |
dc.contributor.author | Rees, M. R. | en |
dc.contributor.author | Patsouras, D. | en |
dc.contributor.author | Katsouras, C. S. | en |
dc.contributor.author | Goudevenos, J. | en |
dc.contributor.author | Pappas, S. | en |
dc.contributor.author | Sourla, E. | en |
dc.contributor.author | Kolettis, T. | en |
dc.contributor.author | Sioros, L. | en |
dc.contributor.author | Zotou, P. | en |
dc.contributor.author | Gartzou-Matsouka, P. | en |
dc.contributor.author | Sideris, D. A. | en |
dc.date.accessioned | 2015-11-24T19:39:35Z | - |
dc.date.available | 2015-11-24T19:39:35Z | - |
dc.identifier.issn | 0174-1551 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/24258 | - |
dc.rights | Default Licence | - |
dc.subject | Analysis of Variance | en |
dc.subject | Angioplasty/*adverse effects | en |
dc.subject | Antibodies, Monoclonal/adverse effects | en |
dc.subject | Anticoagulants/adverse effects | en |
dc.subject | Coronary Angiography/*adverse effects | en |
dc.subject | Early Ambulation | en |
dc.subject | Equipment Failure | en |
dc.subject | Female | en |
dc.subject | Hemostatic Techniques/*adverse effects/*instrumentation | en |
dc.subject | Humans | en |
dc.subject | Immunoglobulin Fab Fragments/adverse effects | en |
dc.subject | Male | en |
dc.subject | Middle Aged | en |
dc.subject | Prospective Studies | en |
dc.subject | Punctures/adverse effects | en |
dc.subject | Radiography, Interventional/adverse effects/instrumentation | en |
dc.title | A prospective randomized trial comparing the safety and efficacy of three commercially available closure devices (Angioseal, Vasoseal and Duett) | en |
heal.type | journalArticle | - |
heal.type.en | Journal article | en |
heal.type.el | Άρθρο Περιοδικού | el |
heal.identifier.primary | 10.1007/s00270-002-1942-9 | - |
heal.identifier.secondary | http://www.ncbi.nlm.nih.gov/pubmed/12132030 | - |
heal.identifier.secondary | http://www.springerlink.com/content/a4glppmd6y8hvqmr/fulltext.pdf | - |
heal.language | en | - |
heal.access | campus | - |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών Υγείας. Τμήμα Ιατρικής | el |
heal.publicationDate | 2002 | - |
heal.abstract | PURPOSE: We compared the safety and efficacy of three closure devices (Angioseal, Vasoseal and Duett) used to close arterial puncture sites in patients who underwent coronary percutaneous procedures. METHODS: A prospective randomized, single-center trial was carried out of consecutive patients who underwent coronary angiography [705 patients: Angioseal (243),Vasoseal (228) and Duett (234)] or angioplasty [146 patients:Angioseal (47), Vasoseal (52) and Duett (47)]. RESULTS: In the angiography patients the device deployment rates were similar, with the Angioseal been significantly slower in achieving hemostasis (p = 0.0001) but resulting in earlier ambulation (p = 0.0001). In the coronary angioplasty patients the deployment rates were similar to those for angiography: time to hemostasis was longer for the Angioseal (p = 0.003), while ambulation times were not different, although prolonged compared with angiography (p = 0.0001). The three devices had similar major complication rates. The Vasoseal had a higher major complication rate after angioplasty than after angiography (p = 0.004). The incidence rate of peripheral embolization was lower when the Angioseal was utilized. Severe complications were mainly seen in patients who received abciximab. CONCLUSIONS: The three closure devices had high rates of successful deployment and were relatively safe. The Angioseal resulted in earlier ambulation after angiography. Utilization of closure devices after abciximab administration possibly increased the complications. | en |
heal.journalName | Cardiovasc Intervent Radiol | en |
heal.journalType | peer-reviewed | - |
heal.fullTextAvailability | TRUE | - |
Appears in Collections: | Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά) - ΙΑΤ |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Michalis-2002-A prospective random.pdf | 81.85 kB | Adobe PDF | View/Open Request a copy |
This item is licensed under a Creative Commons License