Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/22021
Full metadata record
DC FieldValueLanguage
dc.contributor.authorIoannidis, J. P.en
dc.contributor.authorTrikalinos, T. A.en
dc.contributor.authorDanias, P. G.en
dc.date.accessioned2015-11-24T19:20:14Z-
dc.date.available2015-11-24T19:20:14Z-
dc.identifier.issn0735-1097-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/22021-
dc.rightsDefault Licence-
dc.subject*Electrocardiographyen
dc.subjectHumansen
dc.subject*Magnetic Resonance Imagingen
dc.subject*Stroke Volumeen
dc.subject*Tomography, Emission-Computed, Single-Photonen
dc.subject*Ventricular Function, Leften
dc.titleElectrocardiogram-gated single-photon emission computed tomography versus cardiac magnetic resonance imaging for the assessment of left ventricular volumes and ejection fraction: a meta-analysisen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.secondaryhttp://www.ncbi.nlm.nih.gov/pubmed/12084609-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών Υγείας. Τμήμα Ιατρικήςel
heal.publicationDate2002-
heal.abstractOBJECTIVES: The purpose of this study was to evaluate the accuracy of electrocardiogram (ECG)-gated single-photon emission computed tomography (SPECT) for assessment of left ventricular (LV) end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) compared with the gold standard of cardiac magnetic resonance imaging (MRI). BACKGROUND: Several comparisons of ECG-gated SPECT with cardiac MRI have been performed for evaluation of LV volumes and EF, but each has considered few subjects, thus leaving uncertainty about the frequency of discrepancies between the two methods. METHODS: We performed a meta-analysis of data on 164 subjects from nine studies comparing ECG-gated SPECT versus cardiac MRI. Data were pooled in correlation and regression analyses relating ECG-gated SPECT and cardiac MRI measurements. The frequency of discrepancies of at least 30 ml in EDV, 20 ml in ESV and 5% or 10% in EF and concordance for EF < or =40% versus >40% were determined. RESULTS: There was an overall excellent correlation between ECG-gated SPECT and cardiac MRI for EDV (r = 0.89), ESV (r = 0.92) and EF (r = 0.87). However, rates of discrepancies for individual subjects were considerable (37% [95% confidence interval [CI], 26% to 50%] for at least 30 ml in EDV; 35% [95% CI, 23% to 49%] for at least 20 ml in ESV; 52% [95% CI, 37% to 63%] for at least 5% in EF; and 23% [95% CI, 11% to 42%] for at least 10% in EF). The misclassification rate for the 40% EF cutoff was 11%. CONCLUSIONS: Electrocardiogram-gated SPECT measurements of EDV, ESV and EF show high correlation with cardiac MRI measurements, but substantial errors may occur in individual patients. Electrocardiogram-gated SPECT offers useful functional information, but cardiac MRI should be used when accurate measurement is required.en
heal.journalNameJ Am Coll Cardiolen
heal.journalTypepeer-reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά) - ΙΑΤ