Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/21709
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGelalis, L. D.en
dc.contributor.authorXenakis, T. A.en
dc.contributor.authorHantes, M.en
dc.contributor.authorVartziotis, K.en
dc.contributor.authorSoucacos, P. N.en
dc.date.accessioned2015-11-24T19:16:48Z-
dc.date.available2015-11-24T19:16:48Z-
dc.identifier.issn0147-7447-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/21709-
dc.rightsDefault Licence-
dc.subjectAgeden
dc.subject*Computer-Aided Designen
dc.subjectFemaleen
dc.subjectHip Dislocation, Congenital/diagnosis/*surgeryen
dc.subject*Hip Prosthesisen
dc.subjectHumansen
dc.subjectMaleen
dc.subjectMiddle Ageden
dc.subjectPreoperative Careen
dc.subjectProspective Studiesen
dc.subjectProsthesis Designen
dc.subjectSensitivity and Specificityen
dc.subjectTomography, X-Ray Computed/*methodsen
dc.titleThree-dimensional computerized selection of hip prostheses in patients with congenital dislocated hipsen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.secondaryhttp://www.ncbi.nlm.nih.gov/pubmed/11727804-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών Υγείας. Τμήμα Ιατρικήςel
heal.publicationDate2001-
heal.abstractThis study assessed the effectiveness of the combined use of computed tomography (CT) and computer-aided design (CAD) in the preoperative evaluation and implant selection in 20 patients (20 hips) with congenital dislocation of the hip who were scheduled to undergo total hip arthroplasty. Computerized selection of the femoral implant with optimum fit and fill was made after a three-dimensional reconstruction of the femoral canal using CT data and CAD. Implantation of all sizes of 5 noncemented and 2 cemented femoral implants was simulated using CATIA software (IBM, Kingstone, NY). When patients underwent surgery, 18 of 20 preselected prostheses agreed by type and size with the prostheses implanted. The remaining 2 preselected implants agreed by type only. In patients with dislocated and dysplastic hips, combined use of CT and CAD allows effective preoperative planning by providing the surgeon with vital information about the proximal femoral canal geometry and the possible femoral implant with optimum fit and fill to be used.en
heal.journalNameOrthopedicsen
heal.journalTypepeer-reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά) - ΙΑΤ

Files in This Item:
There are no files associated with this item.


This item is licensed under a Creative Commons License Creative Commons