Please use this identifier to cite or link to this item:
https://olympias.lib.uoi.gr/jspui/handle/123456789/16381
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Barney, D. | en |
dc.contributor.author | Bialas, W. | en |
dc.contributor.author | Kokkas, P. | en |
dc.contributor.author | Manthos, N. | en |
dc.contributor.author | Maletic, D. | en |
dc.contributor.author | Papadopoulos, I. | en |
dc.contributor.author | Peisert, A. | en |
dc.contributor.author | Reynaud, S. | en |
dc.contributor.author | Vichoudis, P. | en |
dc.date.accessioned | 2015-11-24T18:30:34Z | - |
dc.date.available | 2015-11-24T18:30:34Z | - |
dc.identifier.issn | 0168-9002 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/16381 | - |
dc.rights | Default Licence | - |
dc.subject | cms | en |
dc.subject | preshower | en |
dc.subject | test beam muon data analysis | en |
dc.subject | detector calibration | en |
dc.title | Detection of muons at 150 GeV/c with a CMS Preshower prototype | en |
heal.type | journalArticle | - |
heal.type.en | Journal article | en |
heal.type.el | Άρθρο Περιοδικού | el |
heal.identifier.primary | DOI 10.1016/j.nima.2006.03.031 | - |
heal.identifier.secondary | <Go to ISI>://000239669500017 | - |
heal.identifier.secondary | http://ac.els-cdn.com/S016890020600550X/1-s2.0-S016890020600550X-main.pdf?_tid=ba558ba1bc906545b2bdf064a4fbbe04&acdnat=1334228544_59065dc9798c5d5e2ebe538c58e31b1a | - |
heal.language | en | - |
heal.access | campus | - |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών και Τεχνολογιών. Τμήμα Βιολογικών Εφαρμογών και Τεχνολογιών | el |
heal.publicationDate | 2006 | - |
heal.abstract | The analysis of 150 GeV/c muon data collected during a test of a CMS Preshower prototype is presented. The test took place in 2004 in the H4 beam at CERN. The muon signal extraction is possible after pedestal subtraction and common mode correction. The results of a Geant-4-based simulation, developed for the Preshower prototype test, are also presented. The results of the simulation are found to be in excellent agreement with the data. It is also demonstrated that by combining the results of the data analysis and simulation an absolute calibration of the CMS Preshower detector system can be performed. (c) 2006 Elsevier B.V. All rights reserved. | en |
heal.journalName | Nuclear Instruments & Methods in Physics Research Section a-Accelerators Spectrometers Detectors and Associated Equipment | en |
heal.journalType | peer reviewed | - |
heal.fullTextAvailability | TRUE | - |
Appears in Collections: | Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά) - ΦΥΣ |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Barney-2006-Detection of muons a.pdf | 644.2 kB | Adobe PDF | View/Open Request a copy |
This item is licensed under a Creative Commons License