Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/16276
Full metadata record
DC FieldValueLanguage
dc.contributor.authorCherdhirankorn, T.en
dc.contributor.authorFloudas, G.en
dc.contributor.authorButt, H. J.en
dc.contributor.authorKoynov, K.en
dc.date.accessioned2015-11-24T18:29:37Z-
dc.date.available2015-11-24T18:29:37Z-
dc.identifier.issn0024-9297-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/16276-
dc.rightsDefault Licence-
dc.subjectfluorescence correlation spectroscopyen
dc.subjectliquid n-alkaneen
dc.subjectanomalous diffusionen
dc.subjectsegmental dynamicsen
dc.subjectglass-transitionen
dc.subjectamorphous polymersen
dc.subjectpolystyrene chainsen
dc.subjectmolecular-dynamicsen
dc.subjectsurface-diffusionen
dc.subjectcis-polyisopreneen
dc.titleEffects of Chain Topology on the Tracer Diffusion in Star Polyisoprenesen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.primaryDoi 10.1021/Ma901439u-
heal.identifier.secondary<Go to ISI>://000271756500081-
heal.identifier.secondaryhttp://pubs.acs.org/doi/pdfplus/10.1021/ma901439u-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Επιστημών και Τεχνολογιών. Τμήμα Βιολογικών Εφαρμογών και Τεχνολογιώνel
heal.publicationDate2009-
heal.abstractFluorescence correlation spectroscopy (FCS) was employed to study the effect of chain topology on the small tracer diffusion in linear and star-shaped 1,4-polyisoprenes (PIS) at temperatures well above the glass transition. In the linear polyisoprene, a Fickian diffusion behavior was observed that is characterized by it single diffusion coefficient. In contrast, the diffusion of the same tracers in three-arm star PI wits non-Fickian and could best be described assuming two diffusion modes. The fast mode diffusion has the same magnitude and temperature dependence as the tracer diffusion in linear PI. The slow mode present only in the star polymer is apparently related to topological restrictions that cause retention of the tracer. The temperature dependence of the retention time is very similar to that of the polymer arm relaxation, indicating a direct correlation between the two dynamic processes.en
heal.journalNameMacromoleculesen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά) - ΦΥΣ

Files in This Item:
File Description SizeFormat 
Cherdhirankorn-2009-Effects of Chain Top.pdf886.28 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons