Please use this identifier to cite or link to this item:
https://olympias.lib.uoi.gr/jspui/handle/123456789/12679
Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Xenos, M. | en |
dc.contributor.author | Girdhar, G. | en |
dc.contributor.author | Alemu, Y. | en |
dc.contributor.author | Jesty, J. | en |
dc.contributor.author | Slepian, M. | en |
dc.contributor.author | Einav, S. | en |
dc.contributor.author | Bluestein, D. | en |
dc.date.accessioned | 2015-11-24T17:22:54Z | - |
dc.date.available | 2015-11-24T17:22:54Z | - |
dc.identifier.issn | 0021-9290 | - |
dc.identifier.uri | https://olympias.lib.uoi.gr/jspui/handle/123456789/12679 | - |
dc.rights | Default Licence | - |
dc.subject | prosthetic heart valves (phv) | en |
dc.subject | mechanical heart valves (mhv) | en |
dc.subject | mechanical circulation support (mcs) | en |
dc.subject | computational fluid dynamics | en |
dc.subject | platelet activation | en |
dc.subject | platelet assays | en |
dc.subject | thrombogenic performance | en |
dc.subject | mechanical heart-valves | en |
dc.subject | induced platelet activation | en |
dc.subject | fluid-structure interaction | en |
dc.subject | free emboli formation | en |
dc.subject | blood damage | en |
dc.subject | flow-through | en |
dc.subject | numerical-simulation | en |
dc.subject | shear-stress | en |
dc.subject | experimental validation | en |
dc.subject | mathematical-model | en |
dc.title | Device Thrombogenicity Emulator (DTE) - Design optimization methodology for cardiovascular devices: A study in two bileaflet MHV designs | en |
heal.type | journalArticle | - |
heal.type.en | Journal article | en |
heal.type.el | Άρθρο Περιοδικού | el |
heal.identifier.primary | DOI 10.1016/j.jbiomech.2010.04.020 | - |
heal.identifier.secondary | <Go to ISI>://000282112300023 | - |
heal.identifier.secondary | http://ac.els-cdn.com/S0021929010002320/1-s2.0-S0021929010002320-main.pdf?_tid=cc8d9e80f66d9aeea386a9f381956158&acdnat=1339396086_2cb174bf4da17da23c79c70f92baf593 | - |
heal.language | en | - |
heal.access | campus | - |
heal.recordProvider | Πανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Μαθηματικών | el |
heal.publicationDate | 2010 | - |
heal.abstract | Patients who receive prosthetic heart valve (PHV) implants require mandatory anticoagulation medication after implantation due to the thrombogenic potential of the valve. Optimization of PHV designs may facilitate reduction of flow-induced thrombogenicity and reduce or eliminate the need for post-implant anticoagulants. We present a methodology entitled Device Thrombogenicty Emulator (DTE) for optimizing the thrombo-resistance performance of PHV by combining numerical and experimental approaches. Two bileaflet mechanical heart valves (MHV) designs, St. Jude Medical (SJM) and ATS, were investigated by studying the effect of distinct flow phases on platelet activation. Transient turbulent and direct numerical simulations (DNS) were conducted, and stress loading histories experienced by the platelets were calculated along flow trajectories. The numerical simulations indicated distinct design dependent differences between the two valves. The stress loading waveforms extracted from the numerical simulations were programmed into a hemodynamic shearing device (HSD), emulating the flow conditions past the valves in distinct 'hot-spot' flow regions that are implicated in MHV thrombogenicity. The resultant platelet activity was measured with a modified prothrombinase assay, and was found to be significantly higher in the SJM valve, mostly during the regurgitation phase. The experimental results were in excellent agreement with the calculated platelet activation potential. This establishes the utility of the DTE methodology for serving as a test bed for evaluating design modifications for achieving better thrombogenic performance for such devices. (C) 2010 Elsevier Ltd. All rights reserved. | en |
heal.publisher | Elsevier | en |
heal.journalName | J Biomech | en |
heal.journalType | peer reviewed | - |
heal.fullTextAvailability | TRUE | - |
Appears in Collections: | Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΜΑΘ |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
Xenos-2010-Device Thrombogenici.pdf | 2.31 MB | Adobe PDF | View/Open Request a copy |
This item is licensed under a Creative Commons License