Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/10352
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGiokas, D. L.en
dc.contributor.authorSakkas, V. A.en
dc.contributor.authorAlbanis, T. A.en
dc.date.accessioned2015-11-24T16:55:45Z-
dc.date.available2015-11-24T16:55:45Z-
dc.identifier.issn0021-9673-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/10352-
dc.rightsDefault Licence-
dc.subjectwater analysisen
dc.subjectsolid-phase extractionen
dc.subjectsunscreen agentsen
dc.subjectsunscreen agentsen
dc.subjectproductsen
dc.titleDetermination of residues of UV filters in natural waters by solid-phase extraction coupled to liquid chromatography-photodiode array detection and gas chromatography-mass spectrometryen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.primaryDOI 10.1016/j.chroma.2003.10.114-
heal.identifier.secondary<Go to ISI>://000188200300032-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0021967303020119/1-s2.0-S0021967303020119-main.pdf?_tid=f6af8a6e-349c-11e3-bce6-00000aacb35f&acdnat=1381733631_c7366158dadbac2a6cb3542a62a2457e-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.publicationDate2004-
heal.abstractThis study describes a procedure for the enrichment, separation and quantification of four major UV filters in natural waters. Solid-phase extraction combined with liquid chromatography and photodiode array detection (LC-UV-DAD), and gas chromatography with mass spectroscopy (GC-MS) were employed for the analyses. LC of the four compounds with surfactant-modified hydro-organic eluents gave satisfactory resolution of overlapping peaks. In GC, a significant improvement of the detection limits was attained, but only three compounds could be detected. The method was validated for, and applied to, various water samples prone to UV filter accumulation due to recreational activities. Recoveries from real samples were 86-99% with LOQs as low as 0.5 ng/l depending on the sample volume and the analytical procedure. (C) 2003 Elsevier B.V. All rights reserved.en
heal.publisherElsevieren
heal.journalNameJournal of Chromatography Aen
heal.journalTypepeer reviewed-