Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/10057
Full metadata record
DC FieldValueLanguage
dc.contributor.authorDemertzis, P. G.en
dc.contributor.authorSimal-Gandara, J.en
dc.contributor.authorFranz, R.en
dc.date.accessioned2015-11-24T16:53:43Z-
dc.date.available2015-11-24T16:53:43Z-
dc.identifier.issn0012-0413-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/10057-
dc.rightsDefault Licence-
dc.subjectbiogenic-aminesen
dc.subjectbiological-fluidsen
dc.subject1,6-hexamethylenediamineen
dc.subjectisocyanatesen
dc.subjectfreshen
dc.subjecturineen
dc.subjectmeaten
dc.titleA Convenient Group Method for the Gas-Chromatographic Determination of Aliphatic Diamines in the 4 Official Ec Food Simulantsen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.secondary<Go to ISI>://A1995QL14700001-
heal.languagede-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Χημείαςel
heal.publicationDate1995-
heal.abstractEC Directive 90/128/EEC prescribes for the aliphatic diamines ethylenediamine and hexamethylenediamine specific migration limits (SML) of 12 mg/kg and 2,4 mg/kg. On the other hand, there are no generally accepted methods of analysis available for compliance testing with the given restrictions. Therefore. a simple capillary gas chromatographic method with flame ionization detection was developed for the determination of ethylenediamine and hexamethylenediamine in food simulants. The method is based on a two-phase derivatization procedure with ethyl chloroformate using 1,3-diaminopropane as internal standard. The linearity and reproducibility of calibration curves for both diamines in all four food simulants were excellent. The overall recovery rates were very satisfactory. The detection limits for both diamines were much lower than the corresponding SML-values. The method which is considered to be also applicable to other aliphatic diamines is presented to EC commission and to CEN TC 194/SC 1 for getting approval as an official standard CEN method for specific migration determination of the restricted diamines.en
heal.publisherWissenschaftliche Verlagsgellschaft MBHen
heal.journalNameDeutsche Lebensmittel-Rundschauen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά). ΧΗΜ

Files in This Item:
There are no files associated with this item.


This item is licensed under a Creative Commons License Creative Commons