Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/14052
Full metadata record
DC FieldValueLanguage
dc.contributor.authorBourantas, C. V.en
dc.contributor.authorPlissiti, M. E.en
dc.contributor.authorFotiadis, D. I.en
dc.contributor.authorProtopappas, V. C.en
dc.contributor.authorMpozios, G. V.en
dc.contributor.authorKatsouras, C. S.en
dc.contributor.authorKourtis, I. C.en
dc.contributor.authorRees, M. R.en
dc.contributor.authorMichalis, L. K.en
dc.date.accessioned2015-11-24T17:34:54Z-
dc.date.available2015-11-24T17:34:54Z-
dc.identifier.issn0007-1285-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/14052-
dc.rightsDefault Licence-
dc.subject3-dimensional intracoronary ultrasounden
dc.subjectcoronary atherosclerosisen
dc.subjectadventitial bordersen
dc.subjectcontour-detectionen
dc.subjectsegmentationen
dc.subjectplaqueen
dc.subjectlumenen
dc.subjectinterventionsen
dc.subjectangiographyen
dc.subjectalgorithmsen
dc.titleIn vivo validation of a novel semi-automated method for border detection in intravascular ultrasound imagesen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.primaryDoi 10.1259/Bjr/30866348-
heal.identifier.secondary<Go to ISI>://000226939600006-
heal.identifier.secondaryhttp://bjr.birjournals.org/content/78/926/122.full.pdf-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Μηχανικών Επιστήμης Υλικώνel
heal.publicationDate2005-
heal.abstractThe aim of this works was to evaluate a new semi-automated intravascular ultrasound (IVUS) border detection method. The method was used to identify the lumen and the external elastic membrane or the borders of stents in 80 IVUS images randomly selected from 10 consecutive human coronary arteries. These semi-automated results were compared with observations of two experts. Several indices in each case were obtained in order fully to evaluate the method. The time required for identification of the borders was also recorded. The interobserver variability of the method ranged from 1.21% to 5.61%, the correlation coefficient from 0.98 to 0.99, the slope was close to unity (0.94-1.03), the y intercept close to zero and the Williams index value was close to unity (range 0.67-0.91). The time (mean +/- SD) required for the method to identify the borders of the different vessel layers for the whole IVUS sequence was 5.2 +/- 0.2 min. The results demonstrate that the method is reliable and capable of identifying rapidly and accurately the different vessel layers depicted in IVUS images.en
heal.publisherThe British Institute of Radiologyen
heal.journalNameBritish Journal of Radiologyen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά)

Files in This Item:
File Description SizeFormat 
Bourantas-2005-In vivo validation o.pdf224.1 kBAdobe PDFView/Open


This item is licensed under a Creative Commons License Creative Commons