Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/13715
Full metadata record
DC FieldValueLanguage
dc.contributor.authorKitsara, M.en
dc.contributor.authorPetrou, P.en
dc.contributor.authorKontziampasis, D.en
dc.contributor.authorMisiakos, K.en
dc.contributor.authorMakarona, E.en
dc.contributor.authorRaptis, I.en
dc.contributor.authorBeltsios, K.en
dc.date.accessioned2015-11-24T17:32:21Z-
dc.date.available2015-11-24T17:32:21Z-
dc.identifier.issn0167-9317-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/13715-
dc.rightsDefault Licence-
dc.subjectreflectance spectroscopyen
dc.subjectatomic force microscopyen
dc.subjectbiomolecular layeren
dc.subjectgamma-globulinsen
dc.subjectellipsometryen
dc.subjectadsorptionen
dc.subjectsurfacesen
dc.subjectarraysen
dc.subjectafmen
dc.titleBiomolecular layer thickness evaluation using White Light Reflectance Spectroscopyen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.primaryDOI 10.1016/j.mee.2009.11.082-
heal.identifier.secondary<Go to ISI>://000276300700030-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0167931709007370/1-s2.0-S0167931709007370-main.pdf?_tid=c14f201f8f00d2c47b0042ce506c519c&acdnat=1339662483_9c103218051f13aa7d604bc280520897-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Μηχανικών Επιστήμης Υλικώνel
heal.publicationDate2010-
heal.abstractA White Light Reflectance Spectroscopy (WLRS) methodology is applied in the evaluation of the effectiveness of biomolecules immobilization onto solid surfaces as well as their subsequent reaction with counterpart biomolecules via measuring the respective layers thickness. In particular we investigated the adsorption of rabbit and mouse gamma-globulins as well as their reaction with complementary antibodies. The results obtained with the proposed methodology were compared with those received by atomic force microscopy analysis of the same samples. It was found that the developed method provides a simple, very fast and accurate approach for thin biomolecular layers thickness determination. (C) 2009 Elsevier B.V. All rights reserved.en
heal.publisherElsevieren
heal.journalNameMicroelectronic Engineeringen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά)

Files in This Item:
File Description SizeFormat 
Beltsios-2010-Biomolecular layer thickness.pdf539.61 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons