Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/13636
Full metadata record
DC FieldValueLanguage
dc.contributor.authorPapaloukas, C.en
dc.contributor.authorFotiadis, D. I.en
dc.contributor.authorLikas, A.en
dc.contributor.authorStroumbis, C. S.en
dc.contributor.authorMichalis, L. K.en
dc.date.accessioned2015-11-24T17:31:52Z-
dc.date.available2015-11-24T17:31:52Z-
dc.identifier.issn0022-0736-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/13636-
dc.rightsDefault Licence-
dc.subjectcomputerized detection of ecg changesen
dc.subjectst-segment episodesen
dc.subjectt-wave episodesen
dc.subjectmedical expert systemen
dc.titleUse of a novel rule-based expert system in the detection of changes in the ST segment and the T wave in long duration ECGsen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.secondary<Go to ISI>://000173615900004-
heal.identifier.secondaryhttp://ac.els-cdn.com/S0022073602296351/1-s2.0-S0022073602296351-main.pdf?_tid=16a39a5e3fb5bcd4368b1244bae579eb&acdnat=1339758364_bf9f85721cc95e4a7835f7e26cc0872f-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Μηχανικών Επιστήμης Υλικώνel
heal.publicationDate2002-
heal.abstractThe development of a new fast and robust computerised system is examined in detecting electrocardiogram (ECG) changes in long duration ECG recordings. The system distinguishes these changes between ST-segment deviation and T-wave alterations and can support the produced diagnosis by providing explanations for the decisions made. The European Society of Cardiology ST-T Database was used for evaluating the performance of the system. Sensitivity and positive predictive accuracy were the performance measures used and the proposed system scored 92.02% and 93.77%, respectively, in detecting ST-segment episodes and 91.09% and 80.09% in detecting T-wave episodes. By using the chi-square test we also compared the performance of the system between ECG recordings with minimal and Substantial amount of noise. The sensitivity of the proposed system is higher than of other algorithms reported in the literature and the positive predictive accuracy is comparable to, or better than, most of them.en
heal.publisherElsevieren
heal.journalNameJ Electrocardiolen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά)

Files in This Item:
File Description SizeFormat 
Papaloukas-2002-Use of a novel rule-.pdf177.38 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons