Please use this identifier to cite or link to this item: https://olympias.lib.uoi.gr/jspui/handle/123456789/13634
Full metadata record
DC FieldValueLanguage
dc.contributor.authorGaliotis, C.en
dc.contributor.authorPaipetis, A.en
dc.contributor.authorMarston, C.en
dc.date.accessioned2015-11-24T17:31:51Z-
dc.date.available2015-11-24T17:31:51Z-
dc.identifier.issn0377-0486-
dc.identifier.urihttps://olympias.lib.uoi.gr/jspui/handle/123456789/13634-
dc.rightsDefault Licence-
dc.subjectstress transfer efficiencyen
dc.subject2-dimensional compositesen
dc.subjectfiberen
dc.subjectspectroscopyen
dc.subjectstrengthen
dc.titleUnification of fibre/matrix interfacial measurements with Raman microscopyen
heal.typejournalArticle-
heal.type.enJournal articleen
heal.type.elΆρθρο Περιοδικούel
heal.identifier.secondary<Go to ISI>://000083469400007-
heal.languageen-
heal.accesscampus-
heal.recordProviderΠανεπιστήμιο Ιωαννίνων. Σχολή Θετικών Επιστημών. Τμήμα Μηχανικών Επιστήμης Υλικώνel
heal.publicationDate1999-
heal.abstractThe effect of specimen geometry upon the parameters that govern the stress transfer (transfer length, interfacial shear strength, positively affected length and stress concentration-factor) in a carbon fibre/epoxy composite was examined in detail. Five frequently employed composite geometries were considered: single fibre composite coupons incorporating discontinuous and continuous carbon fibres, multi-fibre composite tapes with a controlled inter-fibre separation, four-ply unidirectional coupons, and, finally, impregnated fibre rows. The chemistry and the curing characteristics of the matrix were kept unaltered regardless of specimen geometry. All fibre stress measurements were conducted by means of Raman microscopy, The experimental results showed that the transfer length, positively affected length (PAL) and the interfacial shear stress obtained at the location of a fibre fracture are not considerably affected by specimen geometry. In contrast, the residual fibre stress of the unloaded specimens and the stress concentration factors obtained in fibres adjacent to a fibre fracture site were found to be significantly dependent upon fibre volume fraction and specimen geometry. Copyright (C) 1999 John Wiley & Sons, Ltd.en
heal.publisherJohn Wiley & Sons, Ltden
heal.journalNameJournal of Raman Spectroscopyen
heal.journalTypepeer reviewed-
heal.fullTextAvailabilityTRUE-
Appears in Collections:Άρθρα σε επιστημονικά περιοδικά ( Ανοικτά)

Files in This Item:
File Description SizeFormat 
Paipetis-1999-Unification of fibre matrix.pdf370.45 kBAdobe PDFView/Open    Request a copy


This item is licensed under a Creative Commons License Creative Commons